Introduction Introduction
  The SCARA acronym stands for Selective Compliant Assembly Robot Arm and is one that is hard to remember. It's also sometimes referred to as: Selective Compliant Articulated Robot Arm.
     
SCARA robots SCARA robots
automate.it SCARA

automate.it SCARA robot

 

In general, traditional SCARA’s are 4-axis robot arms, i.e., they can move to any X-Y-Z coordinate within their work envelope. There is a fourth axis of motion which is the wrist rotate (Theta-Z). The ‘X’, ‘Y’ and the ‘Theta-Z’ movements are obtained with three parallel-axis rotary joints. The vertical motion is usually an independent linear axis at the wrist or in the base.

By virtue of the SCARA’s parallel-axis joint layout, the arm is slightly compliant in the X-Y direction but rigid in the ‘Z’ direction, hence the term: Selective Compliant. This is advantageous for many types of assembly operations, e.g., inserting a round pin in a round hole without binding.

The second attribute of the SCARA is the jointed two-link arm layout similar to our human arms, hence the often-used term, Articulated. This feature allows the arm to extend into confined areas and then retract or “fold up” out of the way. This is advantageous for transferring parts from one cell to another or for loading/ unloading process stations that are enclosed.

SCARA’s are generally faster and cleaner than comparable Cartesian systems. Their single pedestal mount requires a small footprint and provides an easy, unhindered form of mounting. On the other hand, SCARA's can be more expensive than comparable Cartesian systems and the controlling software requires inverse kinematics for linear interpolated moves. This software typically comes with the SCARA though and is usually transparent to the end-user.

 
More information about the automate.it scara Robot
 
Choose an application note Choose an application note
 
No Title Description Click to see this application note
LA235 automate.it scara robot scara robot for laboratory applicationsmanufacturer's specification sheet download application note LA235_ai_SCARA_Spec_Sheet.pdf
LA235
LA280 automate.it SpaceLAB nano/micro system Dispense nanolitres with an Innovadyne Nanodrop and then dissolve download application note LA280_automate_it_nanodispensing.pdf
LA280
LA282 Automated Nanodispensing with the Labcyte Echo 550 Automated Nanodispensing with the Labcyte Echo 550 download application note LA282_Automated_Nanopipetting_by_Labcyte_550 .pdf
LA282
LA246 Automation of Matrix products Automation of the liquid handlers and barcode readers download application note LA246_Automated_Matrix_Products.pdf
LA246
LA315 Bio-Rad Bio-Plex with a automate.it scara robot Automated Bio-Rad Bio-Plex plate reader with a automate.it scara robot download application note LA315_biorad_ai_SCARA.pdf
LA315
LA250 Deerac Equator Automation of the Deerac Equator Nanopipettor download application note LA250_Automated_Deerac_Equator.pdf
LA250
LA283 automate.it range of pipetting stations The automate.it range of pipetting stations with 8 - 384 channels download application note LA283_di_pipettors.pdf
LA283
LA234 GE Healthcare IN Cell 1000 with KinEDx robot Automation of the GE Healthcare IN Cell 1000 with a KiNEDx robot download application note LA234_GE_InCell_1000_SCARA.pdf
LA234
LA322 GE IN Cell 1000 with Overlord2, standard automated scara robot integration Use of Overlord2 to provide a flexible automated IN Cell 1000 system download application note LA322_GE_INCell1000_ai_package.pdf
LA322
LA314 GE LEADseeker with Overlord2, standard automated integration Use of Overlord2 to provide a flexible automated LEADseeker system download application note LA314_GE_LEADseeker_package.pdf
LA314
LA281 High Throughput Cell Analysis Sample preparation prior to image analysis with the GE IN Cell 3000 download application note LA281_Automated_High_Throughput_Cell_Analysis .pdf
LA281
LA251 Innovadyne Nanodrop Automation of the Innovadyne Nanodrop download application note LA251_Automated_Innovadyne_Nanodrop.pdf
LA251
LA243 Luminex 100/ACS plate reader Automated Luminex plate reader download application note LA243_ACS_Luminex_PAA_Twister_I_II.pdf
LA243
LA215 Luminex 100 with automate.it scara robot Automated Luminex plate reader, automate.it scara with Firepower data analysis download application note LA215_Luminex_Biosero_Kinetix.pdf
LA215
LA254 Matrix 2D Barcode Products Automation of the Matrix 2D range of barcode products download application note LA254_Automated_Matrix_2D_barcode products.pdf
LA254
LA242 Plate Reader Automation Automate plate readers from GE Healthcare, Molecular Devices, PerkinElmer, Tecan and Thermo Labsystems download application note LA242_Automation_Of_Plate_Readers.pdf
LA242
LA241 Robot controlled work cells Description of the laboratory robot systems supported by OVERLORD™. Use Hamilton SWAP, Hudson Plate Crane, Mitsubishi, Sands Technology, Titertek Titan, Caliper Twister I & II download application note LA241_Laboratory_Robot_Workcells.pdf
LA241
LA313 Track based automate.it scara The automate.it scara robot with enhanced work area download application note LA313_ai_SCARA_track.pdf
LA313
 
Choose a knowledge base item Choose a knowledge base item
 
Question Click to see this knowledge base item
Can I remove the e-stop from the robot ? view knowledge base entry
automate.it Verticell Robotic Processing Station
 
Choose a manual Choose a manual
 
Manual Click to see this download
automate.it scara robot Manual download application note
 
Choose a news item Choose a news item
 
Title Date Click to see this news item
Forum Labo, paa alliance with Dutscher Scientific Instruments 10/06/2008 view news item
HET 08 show a success in Holland 21/05/2008 view news item
Need your robot to run at 4°C ? 08/05/2008 view news item
paa launch automate.it scara with electric gripper at J&J 13/06/2008 view news item
paa supplied automated IN Cell system reported 21/12/2007 view news item
paacman shows high content screening automation system 30/04/2008 view news item
Planet XMAP 2007 paa on Bio-Rad booth 01/10/2007 view news item
PRESS RELEASE: GE Healthcare 20/01/2008 view news item
San Francisco 10 Jan 08: See the GE IN Cell 1000 automated workcell controlled by Overlord in San Francisco 09/01/2008 view news item
Satisfied customer in Scotland 26/04/2008 view news item
 
Choose a publication Choose a publication
 
Document Description Click to see this download
"Automated Workflow Optimisation and Assay Development Strategies for High Content Research Facility, Trinity College Dublin" Summary of high throughput technologies used at Trinity College Dublin. e-mail for reprint Contact PAA for this document
"Automating the Bio-Rad Bio-Plex plate reader" Automation of a Bio-Rad Bio-Plex bead plate reader download publication
"Automation of the Labcyte Echo 550" The Labcyte Echo 550 instrument is one of the devices of choice for nanolitre sample transfers.  Automation of the device with data handling enhances the productivity of the instrument significantly. Integrating with a data system allows cherry picki download publication
"Development of a Fully-Integrated Echo Dosing System for Cell-Based Assays" The Cell Screening Group in AstraZeneca has proven that the Labcyte Echo acoustic reformatter is a reliable and accurate platform for the dosing of test compounds in cell-based screening. As the compound dosing step can be time-consuming, and it is i download publication
"Maximizing Investment Automated solutions of GE Healthcare technology platforms" Presentation on how to maximise investment for expensive equipment such as high content screening instruments. Presented at the GE Healthcare Technology Conference & user group meeting. download publication
 
Choose an technical note Choose an technical note
 
No Title Description Click to see this technical note
LATN116 How do I reteach an automate.it KiNEDx robot Instruction manual for the automate.it KiNEDx robot download technical note LATN116_KiNEDxRobotReteach.pdf
LATN116
LATN123 Safety of an automate.it scara robot Relevant safety information for installing a scara robot in your laboratory download technical note LATN123_automate.it_safety_discussion.pdf
LATN123
 
alt="Choose Choose a video
 
Workcell title Showing this equipment Click to see this video
automate.it scara 470 & 660, axes of movement automate.it scara Robot Click to watch video
automate.it scara robot animation modes of movement automate.it scara Robot Click to watch video
automate.it scara robot degrees of freedom/movement automate.it scara Robot Click to watch video
automate.it scara, inverted for reduced footprint automate.it scara Robot Click to watch video
BioTek uFill, bulk reagent addition automated with an automate.it scara robot automate.it scara Robot
BioTek uFill
Click to watch video
BMG Plate reader, automated with an automate.it scara robot automate.it scara Robot
BMG POLARstar reader
Click to watch video
Deerac Equator, nanopipetting automated with an automate.it scara robot automate.it scara Robot
Deerac Equator
Click to watch video
automate.it TPS and read with a Molecular Devices Spectomax automated with an automate.it scara automate.it scara Robot
automate.it TPS24 Pipetting Robot
Molecular Devices SPECTRAMAX 190 reader
Click to watch video
Genomic Solutions Hummingbird, Round Robin processing with an automate.it scara robot automate.it scara Robot
Genomic Solutions Hummingbird Dispenser
Barcode Reader Serial
Click to watch video
Innovadyne Nanodrop, nanopipetting automated with an automate.it scara robot automate.it scara Robot
Innovadyne Nanodrop
Click to watch video
Labcyte Echo 550, automated with an automate.it scara robot with sample tracking Barcode Reader Serial
Labcyte Echo 520 and 55x Nanolitre Dispenser
automate.it scara Robot
Click to watch video
Matrix WellMate, bulk reagent filling autom,ated with an automate.it scara robot Thermo WellMate
automate.it scara Robot
Click to watch video
   
More Information Contact Information
 

If you require any more information or have any questions about these products, please contact us:

 
Copyright 2004-2008 paa | XHTML | CSS
All manufacturers' trademarks are gratefully acknowledged. paa is the trademark of Process Analysis & Automation Ltd.